Smooth and easy operation
Some people are not good at operating computers. So you might worry about that the Lync 2013 Depth Support Engineer Exam certification materials are not suitable for you. Try to believe us. Our experts have taken your worries seriously. They have made it easy to operate for all people. Even if you know little about computers, you can easily begin to do exercises of the 74-338 real exam torrent. Also, we have invited for many volunteers to try our study materials. The results show our products are suitable for them. In addition, the system of our 74-338 test training is powerful. You will never come across system crashes. The system we design has strong compatibility. High speed running completely has no problem at all.
Available for three versions to facilitate your study
Various study forms are good for boosting learning interests. So our company has taken all customers'requirements into account. Now we have PDF version, windows software and online engine of the Lync 2013 Depth Support Engineer Exam certification materials. Although all contents are the same, the learning experience is totally different. First of all, the PDF version 74-338 certification materials are easy to carry and have no restrictions. Then the windows software can simulate the real test environment, which makes you feel you are doing the real test. The online engine of the 74-338 test training can run on all kinds of browsers, which does not need to install on your computers or other electronic equipment. All in all, we hope that you can purchase our three versions of the 74-338 real exam torrent.
Less time input
Learning is just a part of our life. We do not hope that you spend all your time on learning the Lync 2013 Depth Support Engineer Exam certification materials. Life needs balance, and productivity gives us a sense of accomplishment and value. So our 74-338 real exam torrent files have simplified your study and alleviated your pressure from study. It is our goal that you study for a short time but can study efficiently. At present, thousands of candidates have successfully passed the 74-338 exam with less time input. In fact, there is no point in wasting much time on invalid input. As old saying goes, all work and no play makes jack a dull boy. Our 74-338 certification materials really deserve your choice. Contact us quickly. We are waiting for you.
Get the Lync 2013 Depth Support Engineer Exam certification to validate your expertise and broaden your network to get more improvement in your career. We will help you with its valid and high quality 74-338 prep torrent. 74-338 questions & answers are compiled by our senior experts who with rich experience. Besides, we check the update about Lync 2013 Depth Support Engineer Exam certification materials every day. If there is any update, the newest and latest information will be added into the 74-338 complete materials, while the old and useless questions will be removed of the 74-338 torrent. The high quality and high pass rate can ensure you get high scores in the 74-338 actual test.
Microsoft Lync 2013 Depth Support Engineer Sample Questions:
1. Your network environment includes Microsoft Lync Server 2013. You configure a Session Initiation Protocol (SIP) trunk to point to a Lync Mediation Server from an internet service provider (ISP). Media bypass is disabled. You attempt to forward calls to a mobile phone and receive the following message: "Cannot complete the transfer." You need to be able to forward calls to mobile phones. Which cmdlet should you use?
A) Set-CsTrunkConfiguration -EnableSessionTimer $True
B) Set-CsTrunkConfiguration -RTCPActiveCalls $True
C) Set-CsTrunkConfiguration -EnableBypass $True
D) Set-CsTrunkConfiguration -EnableReferSupport $False
2. You plan to deploy Microsoft Lync Server 2013 Enterprise with a side-by-side upgrade from Microsoft Lync Server 2010. You update the schemas, forest, and domain successfully. The Lync Server 2013 topology builder is now providing topology builder functionality for both Lync Server 2010 and Lync Server 2013 environment. The Central Management Store master is on the Lync Server 2010 pool. You recently deployed
a Lync Server 2013 Edge Server, and all Lync services have been running. On Lync Server Management Shell at CMS master, you execute the Get- CsManagementStoreReplicationStatus command. You discover that the Edge Server displays the value False in the UpToDate field, and the LastStatusReport field shows no date. You need to determine the cause of the replication error. What should you do?
A) Start OCSLogger on the Lync Server 2013 Edge Server and select the following components: S4 SIPStack component
B) Start OCSLogger on the Lync Server 2010 Front End Server and select the following components: ServerTransportAdapter Dlx
C) Start ClsController.exe on the Lync Server 2013 Front End Server and specify the UserReplicator scenario.
D) Start OCSLogger on the Lync Server 2010 Front End Server and select the following components: XDS_Master_Replicator XDS_File_Transfer_Agent XDS_Replica_Replicator
3. DRAG DROP You deploy a Microsoft Lync Server 2013 Enterprise pool named Lync2013.contoso.local.
The pool is configured with
the Session Initiation Protocol (SIP) domain litware.com. The environment includes the following:
-a Front End Server named Lync2013FE1
-a Back End Server named Lync2013BE
-an Edge Server named Lync2013Edge that is a member of Edge pool Edgepool.contoso.local
Your Lync 2013 topology supports the following access, meeting, administration, and external web service URLs:
-https://Dialin.litware.com
-https://Meet.litware.com
-https://Admin.contoso.local
-https://external.litware.com
You want to support external Lync Web App clients.
You plan to publish Lync 2013 HTTP Web services through a reverse proxy. You need to issue a certificate to publish Lync 2013 Web services through a reverse proxy firewall. Which three steps should you perform in sequence? (To answer, move the appropriate three actions from the list of actions to the answer area and arrange them in the correct order.)
4. You support a customer whose network environment includes Microsoft Lync Server 2013 Standard deployed with an Edge Server that is connected to the Internet. Some users have Lync Mobile installed on their mobile devices.When the users attempt to sign in to Lync from their mobile devices on a carrier network, they receive the following error message: "Cannot connect to the server. It might be unavailable. Also please check your network connection, sign-in address, and server addresses." You need to ensure that users are able to sign in to Lync from their mobile devices on a carrier network. What should you do?
A) Add a LyncDiscover DNS entry that points to the Lync Front End Pool Server by using a reverse proxy.
B) Add a LyncDiscoverlnternal DNS entry that points to the Lync Edge Server.
C) Add a LyncDiscover DNS entry that points to the Lync Edge Server.
D) Add a LyncDiscoverlnternal DNS entry that points to the Lync Front End Pool Server by using a reverse proxy.
5. You support a customer whose network environment includes a Microsoft Lync Server 2013 Enterprise Pool configured with Enterprise Voice and dial-in conferencing. All servers run Windows Server 2012, and all client computers run Windows 7 64-bit. All users dial in to conferences. Users report that dial-in conferencing settings are not consistent between sites, and that this is affecting their
conferencing experience. You need to ensure that dial-in conferencing settings are consistent between all Lync sites. What should you do?
A) Modify the global settings, and then run the Remove- CSDialInConferencingConfiguration cmdlet against each site.
B) Run the Remove-CsConferenceDirectory cmdlet.
C) Run the Remove-CSDialInConferencingConfiguration cmdlet against the global dial-in conferencing settings.
D) Run the Move-CsConference Directory cmdlet.
Solutions:
| Question # 1 Answer: D | Question # 2 Answer: D | Question # 3 Answer: Only visible for members | Question # 4 Answer: A | Question # 5 Answer: A |
Instant Download: Our system will send you the 74-338 braindumps files you purchase in mailbox in a minute after payment. (If not received within 12 hours, please contact us. Note: don't forget to check your spam.)







